Please use this identifier to cite or link to this item:
http://dspace2020.uniten.edu.my:8080/handle/123456789/7555
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ahmad, J. | |
dc.contributor.author | Purbolaksono, J. | |
dc.contributor.author | Kadir, A.K. | |
dc.contributor.author | Rahman, M.M. | |
dc.date.accessioned | 2018-01-11T09:52:24Z | - |
dc.date.available | 2018-01-11T09:52:24Z | - |
dc.date.issued | 2011 | |
dc.identifier.uri | http://dspace.uniten.edu.my/jspui/handle/123456789/7555 | - |
dc.description.abstract | This paper presents failure investigation on reheater pendent SA213-T22 tubes through visual inspections, steam-side scale and tube wall thickness measurements, metallurgical examinations, and creep analysis. The investigations were carried out following subsequent tube failures of the reheater pendent region of a boiler unit. Interaction event of significant internal scale formation causing the higher metal temperature and external scale exfoliation as a result of high-temperature corrosion is identified to cause the failure of the reheater pendent tube. Prevention actions are recommended to avoid similar failures in the future. © 2011 American Society of Mechanical Engineers. | |
dc.title | Failure investigation on reheater pendent tubes due to external scale exfoliation and internal scale formation | |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
Appears in Collections: | COE Scholarly Publication |
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.