Please use this identifier to cite or link to this item: http://dspace2020.uniten.edu.my:8080/handle/123456789/7555
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAhmad, J.
dc.contributor.authorPurbolaksono, J.
dc.contributor.authorKadir, A.K.
dc.contributor.authorRahman, M.M.
dc.date.accessioned2018-01-11T09:52:24Z-
dc.date.available2018-01-11T09:52:24Z-
dc.date.issued2011
dc.identifier.urihttp://dspace.uniten.edu.my/jspui/handle/123456789/7555-
dc.description.abstractThis paper presents failure investigation on reheater pendent SA213-T22 tubes through visual inspections, steam-side scale and tube wall thickness measurements, metallurgical examinations, and creep analysis. The investigations were carried out following subsequent tube failures of the reheater pendent region of a boiler unit. Interaction event of significant internal scale formation causing the higher metal temperature and external scale exfoliation as a result of high-temperature corrosion is identified to cause the failure of the reheater pendent tube. Prevention actions are recommended to avoid similar failures in the future. © 2011 American Society of Mechanical Engineers.
dc.titleFailure investigation on reheater pendent tubes due to external scale exfoliation and internal scale formation
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:COE Scholarly Publication