Please use this identifier to cite or link to this item: http://dspace2020.uniten.edu.my:8080/handle/123456789/20771
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAl-Shetwi A.Q.en_US
dc.contributor.authorHannan M.A.en_US
dc.contributor.authorJern K.P.en_US
dc.contributor.authorAlkahtani A.A.en_US
dc.contributor.authorAbas A.E.P.G.en_US
dc.date.accessioned2021-08-01T13:41:57Z-
dc.date.available2021-08-01T13:41:57Z-
dc.date.issued2020-
dc.identifier.urihttp://dspace2020.uniten.edu.my:8080/handle/123456789/20771-
dc.description.abstractThe generation and integration of photovoltaic power plants (PVPPs) into the utility grid have increased dramatically over the past two decades. In this sense, and to ensure a high quality of the PVPPs generated power as well as a contribution on the power system security and stability, some of the new power quality requirements imposed by different grid codes and standards in order to regulate the installation of PVPPs and ensure the grid stability. This study aims to investigate the recent integration requirements including voltage sag, voltage flicker, harmonics, voltage unbalance, and frequency variation. Additionally, compliance controls and methods to fulfill these requirements are developed. In line with this, a large-scale three-phase grid-connected PVPP is designed. A modified inverter controller without the use of any extra device is designed to mitigate the sage incidence and achieve the low-voltage ride-through requirement. It can efficiently operate at normal conditions and once sag or faults are detected, it can change the mode of operation and inject a reactive current based on the sag depth. A dynamic voltage regulator and its controller are also designed to control the voltage flicker, fluctuation, and unbalance at the point of common coupling between the PVPP and the grid. The voltage and current harmonics are reduced below the specified limits using proper design and a RLC filter. The obtained results show that the proposed controller fulfilled the recent standard requirements in mitigating power quality (PQ) events. Thus, this study can increase the effort towards the development of smooth PVPP integration by optimizing the design, operation and control strategies towards high PQ and green electricity. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.en_US
dc.language.isoenen_US
dc.titlePower quality assessment of grid-connected PV system in compliance with the recent integration requirementsen_US
dc.typearticleen_US
item.cerifentitytypePublications-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextreserved-
item.openairetypearticle-
Appears in Collections:UNITEN Ebook and Article
Files in This Item:
File Description SizeFormat 
This document is not yet available.pdf
  Restricted Access
396.12 kBAdobe PDFView/Open    Request a copy
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.